Thermal-hydraulic design of a double-tube heat exchanger for acetaldehyde heating
DOI:
https://doi.org/10.5377/nexo.v35i01.13909Keywords:
Acetaldehyde, Pressure drop, Thermal-hydraulic design, Double-tube heat exchanger, Percentage over surfaceAbstract
In the present work, the thermal-hydraulic design of a double tube heat exchanger was accomplished to carry out the heating of acetaldehyde, by using hot water (condensate). A sensitivity study was also carried out to determine the influence of an increase in the acetaldehyde feed rate on six equipment design parameters. The designed heat exchanger will have a total heat transfer area of 3.88 m2, an overall fouled heat transfer coefficient of 613.23 W/m2.K, a total number of hairpins equal to three and a cleanliness factor of 0.80. A pumping power of 2.01 W and 5.78 W is required to impulse the acetaldehyde and water, respectively. The six parameters evaluated in the sensitivity study increase with the increment of the acetaldehyde feed mass flow rate. It is concluded that the designed double tube heat exchanger is adequate from the thermal-hydraulic point of view, since the percentage over surface calculated (25.00%) and the pressure drop of both acetaldehyde (1,158.43 Pa) and water (4,550.70 Pa) are below the maximum allowable limit established by the process.
Downloads
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2022 Array
This work is licensed under a Creative Commons Attribution 4.0 International License.
The authors who publish in Nexo Scientific Journal agree to the following terms:
- Authors retain the copyright and grant the journal the right of the first publication under the license Creative Commons Attribution License https://creativecommons.org/licenses/by/3.0/, which allows others to share the work with a recognition of the authorship of the work and the initial publication in Nexo Scientific Journal.
- Authors may separately establish additional agreements for the non-exclusive distribution of the version of the work published in the journal (for example, in an institutional repository or a book), with the recognition of the initial publication in Nexo Scientific Journal.
- Authors are allowed and encouraged to disseminate their works electronically (for example, in institutional repositories or in their own website) before and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published works.